Inside the appliance
Hood blower, Delay and Auto. In plain English.
A Thermador Professional hood uses a separate remote, in-line or integral blower. DELAY keeps it running for 10 minutes after you finish cooking, then it stops. AUTO lets the hood watch the heat from the cooktop and turn the blower on and off, adjusting every 5 minutes. Only Thermador blowers should be used.

Where it fits.
Hood blower, Delay and Auto in the appliance
The blower sits outside the canopy (remote, in-line or integral); the controls are on the hood front.
The picture stands for a type of component. Which replacement suits your model is a separate question.
What shifts when this system needs a look.
Hood blower, Delay and Auto concerns may show up next to a drop in performance or a message that keeps returning. Testing comes before any verdict on the component.

Thermador hood not venting properly
Thermador’s hood guides blame weak venting on the installation more often than on the hood: it may sit too high or off-center, make-up air may be short, wind may be pushing in through an open window, or the duct may be blocked, too long or full of elbows. Close windows, clear the duct opening, then book a visit.

Thermador hood noisy
Some noise from a Thermador hood is normal, from vibration and moving air. Excessive noise points to the installation: ductwork that is undersized, oversized or loose, a loose transition, or screws not fully tight. Tighten what you can reach, and call us if the noise stays.
Owner care, within the model instructions.
Turn the appliance off and pull the plug before doing any check yourself. Look out for standing water and sharp edges. Never handle a wet plug, remove a service panel or step beyond what your model's guide permits an owner.
- 1
Press DELAY
With the hood off, DELAY starts the blower on high for 10 minutes. With the hood on, it runs on for 10 minutes at the current speed.
- 2
Touch AUTO
AUTO is the automatic mode; the hood control checks the heat and changes settings every 5 minutes.
- 3
Clear the room for air
Close windows and doors if the hood is not venting well, because outside wind can affect it.
- 4
Look for duct trouble
Noise or weak venting can come from loose, undersized or blocked ductwork, per the troubleshooting table.
Cleaning or replacement?
Leave internal testing to a technician.
The hood causes the breaker to trip.
The blower does not run, the breaker is on and the ducts are clear.
Arrange a diagnosticSources and model boundaries.
These documents back up the Hood blower, Delay and Auto guidance. Choose the manual written for your model.
- Use and Care Guide, Professional Series Hoods PH30HWS PH36HWS PH48HWS and others
Match your model to the guide it shipped with. See how we research these pages.
What does DELAY do?
It runs the blower for 10 minutes after pressing it, then the blower stops. It can be set going while the hood is off or already running.
How do I stop DELAY early?
Press a fan speed button, or press 0 to turn the hood off.
How often does AUTO adjust?
Every 5 minutes, based on the amount of heat the hood control detects.
Why is there a flap noise when the hood is off?
The guide says the backflow flap on the duct wall cap moves with the wind. That is normal.
Thermador messages, symptoms, parts, repair visits
Move from the message to your next step.
DELAY lit
DELAY lit on a Thermador hood means the delay shut-off is running: the blower stays on high for 10 minutes and then stops. Wait for the 10 minutes to pass.
Thermador hood not venting properly
Thermador’s hood guides blame weak venting on the installation more often than on the hood: it may sit too high or off-center, make-up air may be short, wind may be pushing in through an open window, or the duct may be blocked, too long or full of elbows. Close windows, clear the duct opening, then book a visit.
Hood repair
Book a diagnostic made for your exact model and performed at the appliance itself.
Find your metro
Where the offices are, and what to tell us about getting in.