Start from the symptom
Thermador beverage center not cooling.
A Thermador glass door refrigerator used as a beverage center that is not cooling may have been switched off: open the door and hold ON/OFF for 3 seconds until the display shows ON. If it is on, the guide points to vents, a warm room, heavy loading or a damaged door gasket.

Start with safe observations.
Turn the appliance off and pull the plug before doing any check yourself. Look out for standing water and sharp edges. Never handle a wet plug, remove a service panel or step beyond what your model's guide permits an owner.
- 1
Is it on
Open the door and hold the ON/OFF button for 3 seconds. The display should show ON.
- 2
Power basics
Start by ruling out an outage, an opened fuse or breaker, and a loose electrical connection.
- 3
Door openings
Do not open the appliance unnecessarily.
- 4
Ventilation openings
Clear the openings at the base of the unit and in the interior.
- 5
Load and room
A large or warm load makes the compressor run more until it cools. So does a hot room or direct sunlight.
- 6
Gasket
A damaged door gasket lets cold air escape. Inspect it.
Systems a technician may investigate.
These parts relate to the symptom, though what you noticed cannot show that any single one has failed.
Look after it the way this appliance's own guide describes.
When observation becomes a service request.
Leave internal testing to a technician.
Switched on and with a clear base, it still fails to cool.
The gasket is damaged.
The compressor runs without pause with a cool load and clear vents.
The HI alarm returns repeatedly.
Arrange a diagnosticSources and model boundaries.
These documents back up the Thermador beverage center not cooling guidance. Choose the manual written for your model.
- Use & Care Guide, Glass Door Refrigerator T24UR925LS T24UR925RS T24UR915LS T24UR915RS T24UR905LP T24UR905RP
Match your model to the guide it shipped with. See how we research these pages.
Why does the compressor run so much?
The guide lists covered vents, a large or warm load, a hot environment and a gasket not sealing.
How do I switch the unit on?
Open the door and press the ON/OFF button for 3 seconds. The display should show ON.
What if drinks are too cold?
Raise the temperature, and rearrange containers so nothing blocks the interior ventilation holes.
The interior light is out. Why?
The guide says the unit may be in Sabbath mode; disengage it.
Thermador messages, symptoms, parts, repair visits
Move from the message to your next step.
HI
HI on a Thermador glass-door refrigerator means the temperature inside is too high. Let warm product cool or remove it, then press the alarm button once.
Thermador beverage center not cooling
A Thermador glass door refrigerator used as a beverage center that is not cooling may have been switched off: open the door and hold ON/OFF for 3 seconds until the display shows ON. If it is on, the guide points to vents, a warm room, heavy loading or a damaged door gasket.
Beverage center cooling modes
Thermador's under-counter glass door refrigerator, which the guide says stores food and beverages, has four temperature modes on its touch panel: BAR at 34 degrees F, QUICK CHILL at 33, FRIDGE at 38 and PANTRY at 53. Each button sets a start point, and QUICK CHILL times out after 24 hours.
Beverage center repair
Book a diagnostic made for your exact model and performed at the appliance itself.
Find your metro
Where the offices are, and what to tell us about getting in.